A heat pump is not automatically cheaper or more expensive than natural gas for an Ontario home. The answer depends on energy prices, performance, how much heating shifts to electricity and which costs the project actually removes.
First name the project: replacing an AC while keeping gas heating, installing coordinated heat-pump/furnace equipment, or converting all relevant appliances so gas service can end. Those choices have different purchase costs and continuing bills. A savings estimate should identify which one it describes.
Three projects, three different comparisons
| Project | Compare | Do not remove by assumption |
|---|---|---|
| AC replacement; gas furnace stays | Complete AC option versus complete heat-pump option, with integration work | Gas account charges and remaining furnace ownership costs |
| Coordinated dual fuel | Heating supplied by each source; compatible equipment and controls | Gas customer charge and backup fuel use |
| Full conversion away from gas | All affected appliances, heating design, electrical work and utility exit scope | Water-heating, cooking or other appliance-conversion costs |
Keeping gas can still be a reasonable project. It simply cannot claim account savings that require disconnection. A full-conversion estimate, meanwhile, needs to include the extra work that makes disconnection possible.
Which gas charges would you actually avoid?
The Ontario Energy Board explains that a fixed customer charge remains payable even when no gas is used during a billing period. Usage-related supply and delivery components need separate treatment.
If heating shifts to electricity while gas service stays active, estimate the gas charges that decline with consumption. Looking only at the commodity line can omit other variable costs. Allocating the entire fixed account charge to the displaced heat can overstate avoided costs.
Use your current bill and applicable tariff, with consistent taxes and a stated date. Do not carry an old calculator’s prices or charges forward without checking them. Any actual utility disconnection terms need confirmation for your account.
Compare the same amount of useful heat
A simplified operating calculation is:
Gas useful-heat cost = avoidable gas dollars per m³ ÷ (fuel energy per m³ × heating efficiency).
Heat-pump useful-heat cost = added electricity dollars per kWh ÷ applicable COP.
NRCan’s fuel-energy table gives representative natural gas energy of 37.5 MJ/m³ and electricity at 3.6 MJ/kWh. Dividing gives about 10.42 kWh/m³ before appliance losses. This is an approximate physical conversion, not your measured gas supply or current price. We do not adopt that older guide’s sample rates or fireplace recommendations.
NRCan’s heat-pump guide explains COP and the distinction between economic and capacity balance points. A cost comparison does not establish that particular equipment can meet your home’s heating requirement.
Worked example: the electricity assumption changes the answer
Hypothetical teaching inputs, October 27, 2026—not current Ontario rates, equipment performance or a 519 quote: avoidable gas $0.50/m³; heating efficiency 95%; added electricity $0.20/kWh.
The gas calculation is $0.50 ÷ ((37.5 ÷ 3.6) × 0.95), or approximately 5.05¢ per useful kWh.
| Hypothetical heat-pump input | Cost per useful kWh | Compared with the example gas cost |
|---|---|---|
| 20¢ electricity; COP 2 | 10.00¢ | Higher |
| 20¢ electricity; COP 3 | 6.67¢ | Higher |
| 20¢ electricity; COP 4 | 5.00¢ | Slightly lower |
| 10¢ electricity; COP 2 | 5.00¢ | Slightly lower |
The simplified crossover COP is about 3.96 at 20¢ electricity, and about 1.98 at 10¢. These are arithmetic thresholds, not recommended thermostat settings or outdoor switchover temperatures.
For a real comparison, ask which COP applies at relevant conditions, what electrical loads are included and how auxiliaries, defrost and backup are represented. A favourable test rating is not automatically a whole-winter result.
The OEB electricity-bill guide identifies fixed and variable charges. Estimate the additional bill caused by heating across the relevant rate periods or tiers; do not blindly use one advertised energy price or the whole bill divided by existing consumption.
A false-savings correction worth checking
Imagine an estimate shows a hypothetical $300 annual fuel saving, adds $360 of avoided gas-account charges and presents $660 total. These amounts are invented for teaching.
If the gas furnace remains as backup and the account stays active, the $360 cannot be counted as avoided merely because gas consumption falls. The example returns to $300 before any other corrections. If the new arrangement adds $100 in annual ownership costs, the simplified net difference becomes $200.
| Hypothetical calculation | Simple payback on a $4,000 incremental purchase |
|---|---|
| $4,000 ÷ incorrectly counted $660 | About 6.1 years |
| $4,000 ÷ corrected $200 | 20 years |
Neither period predicts a real project. Financing, future prices, repair and replacement timing, maintenance differences and cooling value remain outside this example. The lesson is to require evidence for every cost claimed to disappear.
If corrected net savings are zero or negative, a savings-based payback is not established in that scenario. Other goals can be considered separately.
Use the right purchase baseline
If the AC has failed, compare complete alternatives that both address cooling. Specify indoor equipment, electrical work, controls and integration. One outdoor-unit price is not comparable to a complete installed system.
If the AC works and the purchase is mainly intended to reduce winter bills, that is a different starting point. Do not automatically credit an AC replacement you would not otherwise make.
Our AC vs heat pump guide explains the functional difference. Our AC installation guide helps identify system scope. These cost examples do not establish compatibility or remaining furnace life.
Bring this project-boundary checklist
- Name the project: cooling replacement, dual fuel or full conversion.
- List all gas appliances: identify which stay and whether gas service remains.
- Mark each charge: removed, reduced, unchanged or unknown; attach a bill, tariff or written term.
- Request the heating split: how much useful heat is assigned to electricity and gas, under what conditions?
- Ask for equipment evidence: exact model combination, relevant capacity and performance, backup and controls.
- Compare complete installed scopes: include electrical, indoor equipment and other appliance changes where applicable.
- Test uncertainty: show different energy prices and performance, plus a no-incentive scenario.
For a second proposal, use the same assumptions with each contractor. Our quote-comparison guide helps keep exclusions and warranties visible.
Common questions
Can I keep a gas furnace and add a heat pump?
A qualified contractor needs to assess the actual equipment, distribution, electrical requirements and controls. This article’s arithmetic does not establish that any existing furnace accepts any heat pump.
Does changing space heating eliminate the gas bill?
Not while service remains for backup or another appliance. Confirm the account arrangement before counting fixed-charge savings.
Do incentives settle the choice?
Only include an amount after checking current eligibility and process requirements for the actual project. An advertised maximum is not money already secured.
Should I change the switchover temperature myself?
Do not use a cost example as an equipment instruction. Ask the contractor to explain the intended operating sequence and supporting model data.
Compare the project you actually need
Tell 519 Furnace what needs replacing, what you plan to keep and whether ending gas service is a goal. Bring recent bills and model details to the conversation.