Download the free furnace quote checklist
Save it to your phone or print one copy for each quote. The two-page PDF works on iPhone, Android, Mac, Windows and tablets.
Download Free Checklist (PDF) Instant download. No email or sign-up required.A furnace installation quote should identify the exact equipment, the work required to connect it safely, what will be removed, how the system will be tested, the warranty terms and every important exclusion.
If two quotes use different equipment or scopes, the totals cannot tell you which proposal offers better value. Compare the written details before you compare price.
Exact equipment and model numbers
The quote should name the proposed furnace manufacturer and model. It should also identify other major equipment included in the project, such as a thermostat, indoor coil, filter cabinet or accessories.
- Furnace make and model
- Heating input or output information used for the proposal
- Efficiency rating represented accurately
- Blower or staging features that affect the comparison
- Any thermostat, filter or accessory included
A brand name by itself leaves too much room for confusion. Ask for model numbers before signing.
How the furnace was selected for the home
The contractor should explain how the proposed furnace fits the home’s heating needs and existing system. Square footage alone does not describe insulation, windows, air leakage, layout or ductwork.
Ask what information the contractor used and whether any duct or airflow concern needs attention. Oversized equipment can create its own comfort and operating problems, so “bigger” should not serve as the sales argument.
Removal and disposal
Confirm whether the price includes disconnecting, removing and disposing of the old furnace and project debris. If another appliance, oil equipment or unusual access affects the job, the quote should address it instead of leaving the answer for installation day.
Ductwork and equipment transitions
A replacement furnace may not match the dimensions or connection points of the old unit. The proposal should explain any sheet-metal transition, return-air change, filter setup or other duct modification included in the price.
Ask whether visible duct problems or airflow restrictions were found during the assessment and whether the quote includes correcting them.
Gas, venting, drainage and electrical scope
The quote should state which connections the contractor will inspect, reuse, replace or modify. The required work depends on the existing equipment, proposed furnace and conditions in the home.
- Gas or propane connection work
- Combustion-air and exhaust venting
- Condensate drainage
- Electrical power, service switch and wiring
- Thermostat and control wiring
These are contractor tasks. Homeowners should not alter gas, venting, drainage or line-voltage connections to reduce the quote.
Connected air-conditioning equipment
If the furnace shares a blower, controls or cabinet connection with central air conditioning, the contractor should account for that equipment. Ask whether the existing indoor coil, outdoor unit and thermostat will remain compatible with the proposed furnace.
The quote should identify any related work included now and anything that may need attention later.
Startup, testing and homeowner handoff
Installation does not end when the furnace turns on. Ask what startup and commissioning checks the contractor performs and what information you receive before the crew leaves.
- Confirm safe operation and required settings.
- Check airflow and temperature operation as appropriate for the system.
- Confirm thermostat operation.
- Explain filter access and basic homeowner operation.
- Provide model, serial and warranty information.
Warranty, registration and future service
Ask the contractor to separate manufacturer parts coverage from labour coverage. Confirm who handles registration, whether registration affects eligibility, what deadlines apply and what records you should keep.
Do not rely on a single large warranty number without reading what it covers. The equipment, parts, labour and eligibility terms may differ.
Exclusions, changes and payment terms
A strong quote says what it leaves out. Ask how unforeseen work will be documented and approved, what could change the price, when payments are due and whether permits or inspections apply to the specific job.
Do not accept vague language that allows major scope changes without a written conversation.
Real furnace work from 519 Furnace
Real WeatherKing furnace installation from the 519 Furnace project library.
This photo shows why an installation quote needs more than a furnace model. Connections above and around the equipment form part of the actual project scope. Each home needs its own assessment.
Questions to ask before accepting a furnace quote
- What exact furnace and accessories are included?
- How did you select the furnace for this home?
- What duct, gas, venting, drainage, electrical and control work is included?
- What happens to the old equipment?
- How will you test and commission the system?
- What warranties apply to equipment, parts and labour?
- What is excluded, and how are changes approved?
Use the same questions for every contractor. Written answers make proposals easier to compare.
Frequently asked questions
Should the cheapest furnace quote win?
Price matters, but compare equipment, installation scope, testing, warranty and exclusions first. A lower total may cover less work.
Should a furnace quote include a model number?
Yes. A clear proposal should identify the exact furnace and major accessories so you can compare the same information across quotes.
Does a new furnace require ductwork changes?
Sometimes. The answer depends on equipment dimensions, airflow, existing transitions and the condition of the duct system.
Can I ask for a second furnace quote?
Yes. Share the same home and project information with each contractor, then compare the written scope line by line.
Already have a furnace quote?
Ask 519 Furnace for a clear second quote before you decide. Send the existing furnace details, photos and your project goals through the quote form.